Datasheets MeanWell

WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 / 70% RH ℃ CONSTANT CURRENT REGION Note.4 SPECIFICATION MODEL DC VOLTAGE RATED CURRENT RATED POWER OUTPUT VOLTAGE ADJ. RANGE Note.6 CURRENT ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME Note.8 HOLD UP TIME (Typ.) VOLTAGE RANGE Note.5 FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INPUT INRUSH CURRENT(Typ.) LEAKAGE CURRENT SAFETY STANDARDS Note.7 WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSION OTHERS OVER CURRENT Note.4 OVER VOLTAGE OVER TEMPERATURE Can be adjusted by internal potentiometer A type only 500ms, 80ms at full load 230VAC /115VAC 15ms at full load 230VAC /115VAC 90 ~ 305VAC 127 ~ 431VDC 47 ~ 63Hz PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC at full load (Please refer to "Power Factor Characteristic" curve) 7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC <0.75mA / 277VAC 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed Compliance to EN55015, EN55022(CISPR22) Class B, EN61000-3-2 Class C ( 50% load) ; EN61000-3-3 ≧ Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, EN55024, light industry level (surge 4KV), criteria A -40 ~ +70 (Refer to "Derating Curve") ℃ 20 ~ 95% RH non-condensing -40 ~ +85 , 10 ~ 95% RH ℃ ± ℃ ℃ 0.03%/ (0 ~ 60 ) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes UL8750, EN61347-1, EN61347-2-13 independent CSA C22.2 No. 250.13-12, , approved IP65 or IP67 76.9K hrs min. MIL-HDBK-217F (25 ) ℃ 280*144*48.5mm (L*W*H) Protection type : Shut down o/p voltage, re-power on to recover Shut down o/p voltage, re-power on to recover RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 ENVIRONMENT SAFETY & EMC PROTECTION SHORT CIRCUIT Constant current limiting, recovers automatically after fault condition is removed 13 ~ 16V 16.5 ~ 20.5V 22 ~ 26V 26 ~ 30V 32.5 ~ 36.5V 39.5 ~ 43.5V 52.5 ~ 56.5V 46 ~ 50V 59 ~ 63V 92% 92.5% 93.5% 93.5% 94.5% 94.5% 95% 95% 95% 95% 95.5% 95.5% 96% 96% 96% 96% 96% 96% ± 3.0% 20 ~ 40A ± 2.0% 18 ~ 36A ± 1.5% 14 ~ 28A ± 1.0% 12.5 ~ 25A ± 1.0% 10 ~ 20A ± 1.0% 8.3 ~ 16.7A ± 1.0% 6.2 ~ 12.5A ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 2.0% ± 1.5% ± 1.0% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 1.0% 5.6 ~ 11.2A ± 0.5% ± 0.5% ± 1.0% 7.1 ~ 14.3A ± 0.5% ± 0.5% HLG-600H-12 HLG-600H-15 HLG-600H-20 HLG-600H-24 HLG-600H-30 HLG-600H-36 HLG-600H-48 12V 6 ~12V 15V 7.5 ~ 15V 20V 10 ~ 20V 24V 12 ~ 24V 30V 15 ~ 30V 36V 18 ~ 36V 48V 24 ~ 48V 40A 36A 28A 25A 20A 16.7A 12.5A 480W 540W 560W 600W 600W 601.2W 600W 150mVp-p 150mVp-p 12.7 ~ 15.8V 150mVp-p 17 ~ 21V 150mVp-p 20.4 ~ 25.2V 200mVp-p 25.5 ~ 31.5V 250mVp-p 30.6 ~ 37.8V 250mVp-p 40.8 ~ 50.4V 10.2 ~ 12.6V HLG-600H-54 54V 27 ~ 54V 11.2A 604.8W 350mVp-p 45.9 ~ 56.7V HLG-600H-42 42V 21 ~ 42V 14.3A 600.6W 250mVp-p 35.7 ~ 44.1V EMC IMMUNITY EMC EMISSION COLD START 70A(t =1000 s measured at 50% I ) at 230VAC width peak μ TOTAL HARMONIC DISTORTION THD< 20% when output loading 50% at 115VAC/230VAC input and output loading 75% at 277VAC input ≧ ≧ 230VAC 277VAC FUNCTION REMOTE ON/OFF CONTROL Power on : "Hi" >2 ~ 5V or (Open circuit) Power off : "Low" <0 ~ 0.5V or (Short circuit) 600W Single Output Switching Power Supp ly HLG- 60 0H s e r i es File Name:HLG-600H-SPEC 2014-05-12 5V STANDBY 5V : 5V@0.5A ; tolerance 5%, ripple : 100mVp-p(max.) SB ± PACKING 3.9Kg; 4pcs/16.6Kg/0.9CUFT NOTE 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. ℃ 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Constant current operation region is within 50%~100% rated output voltage. This is the suitable operation region for LED related applications, but please reconfirm special electrical requirements for some specific system design. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details. 6. A type only. 7. Safety and EMC design refer to EN60598-1, subject CNS15233, GB7000.1, FCC part18. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time. 9. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. 10. Refer to warranty statement

RkJQdWJsaXNoZXIy MTkzNjc=