Datasheets MeanWell

10A 6.7A 5A 240W 240W 240W 150mVp-p 250mVp-p 250mVp-p 4.0A 240W 350mVp-p 6 ~ 10A 4.0 ~ 6.7A 3 ~ 5A 2.4 ~ 4.0A 2.5A / 115VAC 1.3A / 230VAC 1.2A / 277VAC 27 ~ 34V 43 ~ 52V 52 ~ 63V 62 ~ 85V UL8750,CSA C22.2 No.250.13-12, ENEC EN61347-1, EN61347-2-13 independent, EN62384;GB19510.1,GB19510.14, BIS IS15885(for 48A,60A only), IP65 or IP67 approved EAC TP TC 004, 2.1Kg; 8pcs/18.3Kg/2.09CUFT SPECIFICATION HBG - 2 4 0 se r i e s CONSTANT CURRENT REGION Note.2 MODEL DC VOLTAGE RATED CURRENT RATED POWER Note.5 OUTPUT VOLTAGE RANGE Note.5 FREQUENCY RANGE POWER FACTOR EFFICIENCY (Typ.) Note.7 AC CURRENT (Typ.) INPUT INRUSH CURRENT (Typ.) LEAKAGE CURRENT SAFETY STANDARDS WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSION OTHERS NOTE PACKING OVER CURRENT OVER VOLTAGE OVER TEMPERATURE 90 ~ 305VAC 127 ~ 431VDC 47 ~ 63Hz COLD START 75A(twidth=680 s measured at 50% Ipeak) at 230VAC μ ; Per NEMA 410 <0.75mA / 277VAC 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed 20 ~ 95% RH non-condensing -40 ~ +80 ℃ , 10 ~ 95% RH ± 0.03%/ ℃ (0 ~ 50 ℃ ) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes 663.8K hrs min. Telcordia SR-332 (Bellcore) ; 190.7Khrs min. MIL-HDBK-217F (25 ℃ ) Shut down and latch off o/p voltage, re-power on to recover ENVIRONMENT SAFETY & EMC PROTECTION Shut down o/p voltage, recovers automatically after temperature goes down EMC IMMUNITY EMC EMISSION Note.9 WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 ℃ / 70% RH Compliance to EN55015, EN61000-3-2 Class C (@load ≧ 75%) ; EN61000-3-3, GB17743 and GB17625.1, EAC TP TC 020 Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547,light industry level (surge immunity:Line-Earth:4KV,Line-Line:2KV) , EAC TP TC 020 CURRENT ADJ. RANGE TOTAL HARMONIC DISTORTION MAX. No. of PSUs on 16A CIRCUIT BREAKER 2 units (circuit breaker of type B) / 3 units (circuit breaker of type C) at 230VAC (Please refer to "STATIC CHARACTERISTIC" section) PF>0.98/115VAC, PF>0.95/230VAC, PF>0.93/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section) THD< 20%(@load ≧ 60%/115VC,230VAC; @load ≧ 80%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section) SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed WORKING TEMP. Tcase=-40 ~ +75 ℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section) MAX. CASE TEMP. Tcase=+75 ℃ 240W Constant Voltage + Constant Current LED Driver LINE REGULATION LOAD REGULATION SETUP, RISE TIME Note.6 HOLD UP TIME (Typ.) RIPPLE & NOISE (max.) Note.3 VOLTAGE TOLERANCE Note.4 500ms,120ms /230VAC 2500ms,120ms /115VAC 15ms /115VAC, 230VAC ± 2.0% ± 0.5% ± 0.5% 24V 14.4 ~ 24V HBG-240-24 36V 21.6 ~ 36V HBG-240-36 60V 36 ~ 60V HBG-240-60 48V 28.8 ~ 48V HBG-240-48 Adjustable for A/AB-Type (via built-in potentiometer) 92.5% 92.5% 93.5% 93% ψ 191.5mm *69mm (D * H)  ℃               ℃   ℃  ℃    DALI STANDARDS Compliance to IEC62386-101, 102, 207 for DA-Type only (for DA Type only) 16.8 ~ 24V 25.2 ~ 36V 42 ~ 60V 33.6 ~ 48V CONSTANT CURRENT REGION File Name:HBG-240-SPEC 2019-12-19

RkJQdWJsaXNoZXIy MTkzNjc=