Datasheets MeanWell

40W Constant Voltage + Constant Current LED Driver HLG - 40H se r i es SPECIFICATION MODEL DC VOLTAGE RATED CURRENT RATED POWER OUTPUT VOLTAGE ADJ. RANGE CURRENT ADJ. RANGE LINE REGULATION LOAD REGULATION SETUP, RISE TIME Note.6 HOLD UP TIME (Typ.) VOLTAGE RANGE Note.5 FREQUENCY RANGE POWER FACTOR (Typ.) EFFICIENCY (Typ.) AC CURRENT (Typ.) INPUT INRUSH CURRENT(Typ.) MAX. No. of PSUs on 16A CIRCUIT BREAKER LEAKAGE CURRENT SAFETY STANDARDS Note.8 WORKING TEMP. WORKING HUMIDITY STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION MTBF DIMENSION OTHERS NOTE PACKING OVER CURRENT OVER VOLTAGE OVER TEMPERATURE Adjustable for A/AB-Type only (via built-in potentiometer) Adjustable for A/AB-Type only (via built-in potentiometer) 47 ~ 63Hz 0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC <0.75mA / 277VAC 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed 20 ~ 95% RH non-condensing -40 ~ +80 ℃ , 10 ~ 95% RH ± 0.03%/ ℃ (0 ~ 60 ℃ ) 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes 1131.9K hrs min. Telcordia SR-332 (Bellcore) ; 336.5K hrs min. MIL-HDBK-217F (25 ℃ ) 171*61.5*36.8mm (L*W*H) 0.73Kg; 20pcs/15.6Kg/0.9CUFT Shut down o/p voltage, re-power on to recover RIPPLE & NOISE (max.) Note.2 VOLTAGE TOLERANCE Note.3 ENVIRONMENT SAFETY & EMC PROTECTION Shut down o/p voltage, re-power on to recover WITHSTAND VOLTAGE ISOLATION RESISTANCE I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25 ℃ / 70% RH CONSTANT CURRENT REGION Note.4 18 ~ 24V 15 ~ 21V 23 ~ 30V 28 ~ 35V 35 ~ 43V 41 ~ 49V 48 ~ 58V 59 ~ 68V 54 ~ 65V 86.5% 86.5% 88% 88% 88.5% 88.5% 89.5% 88.5% 89.5% ± 2.5% 2 ~ 3.33A ± 2.0% 1.6 ~ 2.67A ± 1.0% 1.2 ~ 2A ± 1.0% 1 ~ 1.67A ± 1.0% 0.8 ~ 1.34A ± 1.0% 0.67 ~ 1.12A ± 1.0% 0.5 ~ 0.84A ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 2.0% ± 1.5% ± 1.0% ± 0.5% ± 0.5% ± 0.5% ± 0.5% ± 1.0% 0.45 ~ 0.75A ± 0.5% ± 0.5% ± 1.0% 0.58 ~ 0.96A ± 0.5% ± 0.5% 12V HLG-40H-12 HLG-40H-15 HLG-40H-20 HLG-40H-24 HLG-40H-30 HLG-40H-36 HLG-40H-42 HLG-40H-48 HLG-40H-54 7.2 ~12V 15V 9 ~ 15V 20V 12 ~ 20V 24V 14.4 ~ 24V 30V 18 ~ 30V 36V 21.6 ~ 36V 48V 28.8 ~ 48V 3.33A 2.67A 2A 1.67A 1.34A 1.12A 0.84A 39.96W 40.05W 40W 40.08W 40.2W 40.32W 40.32W 150mVp-p 150mVp-p 13.5 ~ 17V 150mVp-p 17 ~ 22V 200mVp-p 22 ~ 27V 200mVp-p 27 ~ 33V 200mVp-p 33 ~ 40V 300mVp-p 44 ~ 53V 10.8 ~ 13.5V 54V 32.4 ~ 54V 0.75A 40.5W 300mVp-p 49 ~ 58V 42V 25.2 ~ 42V 0.96A 40.32W 200mVp-p 40 ~ 46V Compliance to EN55015, EN61000-3-2 Class C ( ≧ 60%) ; EN61000-3-3,GB17743 and GB17625.1, EAC TP TC 020 @ load EMC IMMUNITY EMC EMISSION Note.8 SHORT CIRCUIT Hiccup mode, recovers automatically after fault condition is removed COLD START 50A(t width =210 s measured at 50% I peak ) at 230VAC; Per NEMA 410 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC μ TOTAL HARMONIC DISTORTION 16ms / 115VAC, 230VAC 500ms,80ms/115VAC 500ms,80ms/230VAC THD< 20% (@ load 60% / 115VAC,230VAC; @ load 75% / 277VAC) ≧ ≧ (Please refer to TOTAL HARMONIC DISTORTION (THD) section) " " 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section) PF ≧ 0.98/115VAC, PF ≧ 0.95/230VAC, PF ≧ 0.92/277VAC @ full load (Please refer to " " section) POWER FACTOR (PF) CHARACTERISTIC MAX. CASE TEMP. Tcase= +80 ℃ Tcase= -40 ~ +80 ℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)   ℃            ℃    ℃  ℃    File Name:HLG-40H-SPEC 2019-12-10 UL8750(type”HL”), CSA C22.2 No. 250.0-08 , independent , EN/AS/NZS 61347-1,EN/AS/NZS 61347-2-13 GB19510.1,GB19510.14,EAC TP TC 004,KC61347-1,KC61347-2-13 IP65 or IP67 approved ; (except for AB-type), J61347-1 J61347-2-13 (except for B,AB and D-type) , ; design refer to UL60950-1, TUV EN60950-1, EN60335-1 Compliance to EN61000-4-2,3,4,5,6,8,11; EN61547, EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020

RkJQdWJsaXNoZXIy MTkzNjc=